Technology Advantages
Technology Advantages
With "pioneer of new liquid cooling technology, definer of new cooling technology" as its technological mission, LANXUN has built 11 core technology systems covering thermal performance, permanent magnet drive, water-saving & plume abatement, adiabatic cooling, digital twin, and Industry 4.0 smart manufacturing. The full product range is certified by leading international authorities including US CTI, FM, UL, and EU CE, supporting every commitment with measured data.
Nine Core Technology Platforms
Nine underlying technology platforms shared by the full LANXUN product range — standard across the board and never diluted by product line
World-leading Test Platform & Experimental Database
8000kW heat source, 1300m³/h test capacity, GB + CTI dual standards
Quasi-Industry 4.0 Modular Information Sharing Framework
Automated forming lines, modular information sharing, <10-day delivery cycle
Full GB/T 7190.1-2018 National Standard Performance
The full product range passes all performance tests of the national standard, not just single items
20-Year Fill Molding Technology
Positive/negative pressure fill molding technology, 20-year design life, nuclear-grade quality
48.6dB(A) Ultra-quiet FRP Fan
High-twist airfoil blades, noise 1-2 grades below the national standard
Laser Flying-Cut Stainless Steel Processing
Based on laser flying processing equipment — high precision, burr-free, and highly consistent
Patent Cluster Green Building Solutions
152 patents covering all scenarios of energy saving, water saving, and anti-plume
Alibaba Cloud Smart Manufacturing Platform
An Alibaba Cloud-based intelligent management platform, fully digitalizing the production process
Even-pressure Variable-flow Smart Tower for High-efficiency Plants
Patented constant-pressure water supply + variable-flow even water distribution, 20%-120% variable flow
Applications: the full cooling tower range including PL, LC, HMK, LMB, and integrated units
Even-pressure Variable-flow Water Supply Technology
Prefabricated constant-pressure water troughs and variable-flow nozzles maintain even water distribution across a 20%-120% flow range, delivering significant energy savings at partial load.
Technical Principle & Verification
Inlet water is changed from conventional external piping to axisymmetric in-tower inlet — prefabricated constant-pressure water troughs plus a low-resistance, anti-siphon hydraulic-balancing internal inlet system, with multi-level variable-flow nozzles of different types arranged in the distribution basin to keep even water distribution at partial load. At the Guangzhou Tianhe Park high-efficiency plant project (PL-32463C×4), the measured cumulative average COP of the plant reached 5.84.
Applications: PL Series cooling towers for high-efficiency plants and the cross-flow open circuit series
Permanent Magnet Direct Drive Technology
High-torque permanent magnet synchronous direct drive motors replace conventional "motor + gearbox/belt" transmission — maintenance-free and highly efficient.
Technical Principle & Verification
The permanent magnet synchronous motor drives the fan directly, eliminating mechanical losses in intermediate transmission. Combined with variable-frequency control, it automatically adjusts fan speed based on real-time thermal load, with particularly notable savings at partial load. The cooling towers at Shenzhen Metro Nanshan Book City Station use permanent magnet motors, helping this high-efficiency air-conditioning plant demonstration station enter the COP 5.0 era; all cross-flow towers of Shenzhen Metro Phase IV are equipped with permanent magnet synchronous motors.
Applications: PL Series (optional), PL-C-ZN Smart Cooling Tower, Digital Twin Smart Cooling Tower
Water-saving & Plume Abatement (Anti-Plume) Technology
Combined dry-wet operation switches between wet mode in summer and dry mode in winter, significantly reducing water consumption and eliminating visible plume, with a winter water-saving rate above 85%.
Technical Principle & Verification
LANXUN participated in drafting the association standard "Plume Abatement and Water-saving Mechanical Draft Cooling Towers" (T/CGMA 1001-2021). Plume abatement index >100% (design point: dry-bulb 5°C, RH 85%); the HRN condensing module achieves a 16% annual water-saving rate (a 1000m³/h tower saves about 19,200m³ per year); the gas-liquid wall heat exchange coefficient is 30 times higher than gas-gas heat exchange.
| Technical Route | Principle | Representative Product |
|---|---|---|
| Dual-Path Anti-Plume | Dry/wet air channels mix exhaust to avoid the saturation curve, producing no visible plume | HMK Dual-Path Series |
| Open/Closed Switching | Dual open + closed systems in summer, closed-circuit only in winter | PL Water-saving & Plume Abatement |
| Combined Dry-Wet Operation | Spray stops in winter, heat dissipation via fin structure only | LXWD, LMB-RB Series |
Applications: HMK Dual-Path Anti-Plume, PL open/closed water-saving & plume abatement, LXWD dry-wet combined, LMB-RB counter-flow dry-wet, LMB-F&SF combined-flow, HRN industrial plume abatement tower
Isenthalpic Adiabatic Cooling Technology
Water evaporation absorbs heat to lower the air dry-bulb temperature at constant enthalpy — an efficient cooling method operating without compressors and with zero water consumption.
Technical Principle & Verification
As air passes through the adiabatic pad (wet curtain), water evaporation absorbs the air's sensible heat, lowering the dry-bulb temperature at constant total enthalpy and further reducing the cooling tower inlet water temperature. Optional wet-film or atomizing devices provide adiabatic cooling, with no refrigerant and a wide operating range from -30°C to 50°C. As a pre-cooling module for conventional data center air conditioning, it helps achieve PUE <1.25. Certified by EU CE and US CTI, it is a high-tech product.
Applications: LAD Series isenthalpic adiabatic cooling units
Thermal Performance Laboratory
LANXUN has built China's largest factory cooling tower performance test facility compliant with both Chinese and US standards, replacing theoretical estimates with measured data.
Technical Principle & Verification
Built in 2007 and continuously upgraded: the largest performance test facility in China compliant with national standards and US CTI standards; China's first steam-based cooling tower fill test system and performance test system; the most comprehensive cooling tower physical-chemical and material inspection center in China; precision octave-band acoustic noise testing instruments covering full-dimensional verification of thermal performance, noise spectrum, and drift loss. It is a shared platform for the selection, certification, and R&D of the full product range, and also the site for CTI annual re-inspection.
Applications: Shared platform for selection, certification, and R&D of the full product range
In-house Thermal Software
5 self-developed cooling tower thermal calculation and selection software packages break the US monopoly and form a complete software copyright system.
Technical Principle & Verification
Cooling tower thermal calculation software has long been monopolized by US companies; LANXUN's self-development broke this technical barrier. The in-house software precisely matches China's climate zones, water quality conditions, and project operating conditions, so selection results better fit the actual Chinese market, covering the entire process of equipment inquiry, online selection verification and quotation analysis, selection calculation, quotation inquiry, and online selection configuration services.
Applications: Selection and solution design for the full product range
Industry 4.0 Smart Manufacturing
A smart manufacturing base built to quasi-Industry 4.0 standards, with automated production lines and cloud-based management ensuring product consistency and delivery efficiency.
Technical Principle & Verification
Key equipment includes laser flying-cut machines and multi-function stainless steel bending machines; the management platform is an Alibaba Cloud-based smart manufacturing management cloud platform, fully digitalizing the production process.
| Stage | LANXUN (Industry 4.0) | Conventional Process |
|---|---|---|
| Loading | Automated loading system | Manual handling |
| Cutting | Laser flying-cut | Conventional shearing/cutting |
| Forming | Automated bending line | Manual bending |
| Welding | Robotic welding | Manual welding |
| Surface Treatment | Automated cleaning + galvanizing | Manual grinding + outsourced galvanizing |
| Delivery | <10 days | >30 days |
Applications: Production of the full cooling tower range
Ultra-quiet Noise Reduction Technology
High-twist FRP fans combined with a silencer patent cluster keep tower noise 1-2 noise grades below the national standard.
Technical Principle & Verification
Noise levels are 1-2 grades below the national cooling tower standard; together with a patent cluster of inlet silencers, outlet silencers, and sheet/matrix high-efficiency silencers, it meets the stringent environmental assessment requirements of urban core areas and residential surroundings.
Applications: PL Ultra-quiet Series, HMK Ultra-quiet Series, LC Ultra-low Noise Series, PG negative-pressure series with silencers
Standard Setting & International Certification
LANXUN participates in national and industry standard setting as a drafting unit; its products cover all mainstream certifications in China, the US, Europe, and Japan.
Technical Principle & Verification
Domestic certifications fully cover GB + CCTI + CQC energy-saving + CQC water-saving; international certifications provide quadruple assurance with CTI + FM + UL + CE. The full range is certified separately by product series, meeting the compliance requirements of all kinds of projects at home and abroad.
Applications: Full cooling tower range (certified separately by series)
Patents & R&D Platforms
Sustained high-ratio R&D investment has formed a 152-patent cluster covering structure, heat transfer, water saving, and noise reduction, along with multiple provincial R&D platforms.
Technical Principle & Verification
The company holds platforms such as the Guangdong Engineering Technology Research Center for High-efficiency Energy-saving, Water-saving and Noise-reduction Cooling Systems, a provincial-level enterprise technology center, and a Guangdong Doctoral Innovation Station; it has been awarded National Specialized and Innovative (SRDI) Key "Little Giant" Enterprise (the first in Zhaoqing), National High-Tech Enterprise, Guangdong Manufacturing Single Champion Enterprise, and Guangdong Top 500 Manufacturing Enterprises (No. 376).
Applications: Continuous technological iteration of the full cooling tower range
Intellectual Property & Standards
152 patents · 10 software copyrights · 45 standards participated in (11 national + 28 industry + 6 association standards) — LANXUN has built a solid intellectual property moat
Including 300+ across controlled subsidiaries
Core technology moat
Covering the full product line
11 national + 28 industry + 6 association standards (14 published)
Invention Patent Certificates (Selected)

A Digital Twin Control System for Cooling Tower Circulating Water
Patent No.: ZL 2024 1 1555952.X

Multi-stage Heat Exchange Side-inlet Cross-flow Cooling Tower and Its Multi-stage Heat Exchange Method
Patent No.: ZL 2024 1 1614100.3
Representative Invention PatentsSelected from 34 granted invention patents
A Digital Twin Control System for Cooling Tower Circulating Water
Multi-stage Heat Exchange Side-inlet Cross-flow Cooling Tower and Its Multi-stage Heat Exchange Method
Zoned Water Distribution Water-saving Plume Abatement Counter-flow Cooling Tower
Water-saving Anti-freezing Plume Abatement Counter-flow Cooling Tower
A Matrix-type Silencer with Enlarged Airflow Area
A Production Line for Cooling Tower Structural Components
A Punching Device for Cooling Tower Components
An Open Circuit Cooling System with Concrete Blower for Subway Tunnels
Software Copyrights10 software copyrights covering thermal calculation, intelligent monitoring, and online selection
Participated Standards45 standards in total (11 national + 28 industry + 6 association standards); the 14 published ones are listed below
| No. | Standard Code | Standard Name | Category |
|---|---|---|---|
| 1 | GB/T 7190.1-2018 | Mechanical Draft Cooling Towers - Part 1: Small and Medium Open Circuit Cooling Towers | National Standard |
| 2 | GB/T 7190.2-2018 | Mechanical Draft Cooling Towers - Part 2: Large Open Circuit Cooling Towers | National Standard |
| 3 | GB/T 7190.3-2019 | Mechanical Draft Cooling Towers - Part 3: Closed Circuit Cooling Towers | National Standard |
| 4 | GB/T 44855-2024 | Specification for Water-saving Management of Cooling Towers | National Standard |
| 5 | T/CGMA 1001-2021 | Plume Abatement and Water-saving Mechanical Draft Cooling Towers | Association Standard |
| 6 | T/CECS 1100-2022 | Evaluation Standard for High-efficiency Air-conditioning Refrigeration Plants | Association Standard |
| 7 | T/CECS 10316-2023 | Integrated Smart Energy Station for Buildings | Association Standard |
| 8 | T/CECS 1371-2023 | Technical Specification for Application of Integrated Smart Energy Stations | Association Standard |
| 9 | T/CECS 1544-2024 | Technical Specification for Intelligent Control Systems of High-efficiency Air-conditioning Refrigeration Plants | Association Standard |
| 10 | T/CSTM 01345-2024 | Technical Specification for Composite Material Cooling Tower Structures | Association Standard |
| 11 | T/CAQI 001-2023 | Evaluation Specification for Energy Efficiency Grades of Cooling Towers | Association Standard |
| 12 | T/CI 002-2024 | Technical Specification for Energy Saving of Data Center Cooling Towers | Association Standard |
| 13 | T/CISA 003-2023 | Guidelines for Energy Saving of Industrial Circulating Cooling Water Systems | Association Standard |
| 14 | DB44/T 1234-202X | Guangdong Provincial Standard for Energy Efficiency Limits of Cooling Towers | Local Standard |
To protect core technical assets, the complete patent and software copyright list is not published on the website. To review the full list (for business cooperation, due diligence, or tender qualification verification), pleasecontact usfor an authorized version.
Explore the Technology Zone
Data Center Cooling Solutions
COP up to 10, PUE <1.25, full-path PL + IE + LAD solutions
Water-saving & Plume Abatement Technology
Winter water saving 85%+, 17 patents, 5 product lines
Smart Cooling Tower
Digital twin + 8 intelligent systems, energy consumption reduced by 20%-50%
Get a Technical Solution
The technical parameters above are the common technology platform shared by the full LANXUN product range, and specific project solutions can be customized to operating conditions. For detailed technical solutions or selection support, please contact the LANXUN technical team.
Contact Us Now